+64 09 2424702

sales{at}mindlogik.com

Buy Local and Save $$$

Account

Search

Cart 0 $0.00

Looking for a Specific Product?

Quick Links

MindManager Professional

For personal or business use.

MindManager Enterprise

For enterprise,large organisations and teams of 5 or more users.

MindManager Academic

For teachers, students, academic faculty,  academic site licenses

PHONE – +64 (0)9 8171962

MindManager Government

For government departments.

MindManager Web

A more affordable, less function MindManager rich web version  .

MindManager Icons4Maps

A range of  Icon and Image sets for MindManager

BROWSE ALL OUR PRODUCTS

Email: software@mindlogk.com

Techsmith Snagit and Camtasia

Considered one of the best screen capture and video recording tools.

Cloud Online Storage

Security and storage go hand in hand. Get an annual subscription to Dropbox, Box, OneDrive or Google Drive.

Contact us

Need more help? Please phone, email or use our web form,

As3000 Current Carrying Capacity Table Upd 🆒

| Factor Type | AS/NZS 3000 Clause | Example | |-------------|--------------------|---------| | (e.g., >30°C air) | 3.5.3.1.1 (Table 3.5.3.1.1) | At 40°C, factor = 0.87 for PVC | | Grouping (multiple circuits) | 3.5.3.1.2 (Table 3.5.3.1.2) | 4 circuits touching, factor = 0.68 | | Thermal insulation (cable buried in insulation) | 3.5.3.1.3 | Factor = 0.50 to 0.70 | | Soil thermal resistivity (buried cables) | 3.5.3.1.4 | Factor = 0.85 to 1.0 |

| Typical Table Reference | Description | |------------------------|-------------| | | Single-core cables, copper, V-75/PVC insulation, clipped direct (Method C). | | 3.5.3.1 (ii) | Multi-core cables, copper, V-90/XLPE, in conduit (Method B). | | 3.5.3.2 | Current capacities for aluminium conductors (derated from copper values). | | 3.5.3.3 | Capacities for flexible cords (e.g., AS/NZS 3191). | Note: Always use the table corresponding to the installation method (Table 3.4) first, then find the current capacity. 5. Example Extract (Illustrative – Single-core Copper, 90°C XLPE, Clipped Direct) | Conductor Cross-section (mm²) | Current Carrying Capacity (A) | |-------------------------------|-------------------------------| | 1.0 | 15 | | 1.5 | 19 | | 2.5 | 26 | | 4.0 | 34 | | 6.0 | 43 | | 10.0 | 59 | | 16.0 | 79 | | 25.0 | 104 | as3000 current carrying capacity table

These are representative values; refer to the latest AS/NZS 3000 for exact figures. The base table value is not the final allowable current in most installations. Derating factors must be applied: | Factor Type | AS/NZS 3000 Clause |

My cart
Your cart is empty.

Looks like you haven't made a choice yet.