Pelco released V2.12.0 with anti-rollback counter. Firmware update now requires explicit force parameter for downgrade, which triggers audit log event.
The web interface accepted older firmware images without checking anti-rollback version. Attacker could downgrade to a version with known hardcoded credentials (V2.8.2), gain root access, then re-upgrade while keeping backdoor. pelco firmware
Vx.x.x-xx Example: V1.9.12-2 → Product: Sarix Enhanced 4 Series Pelco released V2